西門子QRC1系列火焰探測器-電眼 |
QRC1系列火焰探測器-電眼
品牌:SIEMENS(西門子)
產地:德國 |
產品介紹 |
Blue-flame detectors for the supervision of blue- or yellow-burning oil or gas flames. Blue-flame detectors are used primarily in connection with burner controls for burners of small capacity in intermittent operation.
-
The QRC1... is a compact UV-sensitive blue-flame detector with an integrated preamplifier.
-
It is designed for frontal and lateral (90°) illumination. This type of flame detector is suited for use with burner controls LOA2... (except LOA25...), LOA3..., LOA44..., LMOx4..., LGB3..., LAL1... and LAL4... and – in terms of plug-in facility – is compatible with the photoresistive detectors QRB1...
-
The spectral sensitivity of the QRC1... is a maximum of approximately 300 nm, which means that it optimally covers the range of UV radiation of blue-burning oil or gas flames. Since the QRC1... is also capable of detecting UV fractions of the radiation spectrum of other luminous sources (e.g. boiler house illumination or sunlight), the usual regulations for extraneous light still apply.
-
The QRC1... may not detect UV radiation of ignition sparks, as otherwise lockout will occur during the prepurge time, due to extraneous light. | |
技術參數 |
主要參數 |
主電壓 |
AC230V -15/+10% |
主頻率 |
50...60Hz ±6% |
功率 |
0.35VA |
火焰信號反應時間 |
300ms |
自帶電纜長度 |
1m最大 |
輔助電纜長度 |
20m最大 |
保護等級 |
IP40 |
安全等級 |
II |
重量(帶350mm線) |
29g | | |
環境條件 |
運輸環境 |
IEC 60 721-3-2 |
內部條件 |
class 2K2 |
機械條件 |
class 2M2 |
溫度范圍 |
-20...+80ºC |
濕度 |
<95% |
運行環境 |
IEC 60 721-3-3 |
內部條件 |
class 3K5 |
機械條件 |
class 3M1 |
溫度范圍 |
-20...+60ºC(可短暫到75ºC) |
濕度 |
<95% |
不得進水 | | | |
|